Product Data SheetJanuary 201400813-0100-4750, Rev FATHE 8750WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering specific to the Wat
10Rosemount 8750WAJanuary 2014www.rosemount.comOptional discrete output function (AX)Externally powered at 5 to 24 VDC, transistor switch closure up t
11Rosemount 8750WAJanuary 2014www.rosemount.comPerformance specifications(System specifications are given using the frequency output and with the unit
12Rosemount 8750WAJanuary 2014www.rosemount.comProcess-wetted materialsLiningPTFEElectrodes316L SST, Nickel Alloy 276 (UNS N10276)Process connectionsM
13Rosemount 8750WAJanuary 2014www.rosemount.comDC load limitations (Analog output)Maximum loop resistance is determined by the voltage level of the ex
14Rosemount 8750WAJanuary 2014www.rosemount.com Table 2. Flanged sensor (ASME unless otherwise noted)Sensor flange ratingNominal line size inches (mm)
15Rosemount 8750WAJanuary 2014www.rosemount.comDimensional drawingsDimensions are in inches (mm).Figure 6. Rosemount 12ES Transmitter 4.31(109)LOI Key
16Rosemount 8750WAJanuary 2014www.rosemount.comFigure 7. Rosemount 32ES TransmitterDimensions are in inches (mm).1/2-14 NPT Electrical Conduit Connect
17Rosemount 8750WAJanuary 2014www.rosemount.comDimensions are in inches (mm).Figure 8. Rosemount Flanged Sensors, typical of 1/2-in. to 4-in. (15 mm t
18Rosemount 8750WAJanuary 2014www.rosemount.com Table 3. Rosemount Flanged Sensor Dimensions in Inches (mm).Refer to dimensional drawings, Figure 8, a
19Rosemount 8750WAJanuary 2014www.rosemount.comFigure 10. Rosemount Wafer Sensors, typical of 1/2-in. and 1-in. (15 mm and 25 mm) line sizes Dimension
2Rosemount 8750WAJanuary 2014www.rosemount.comThe Rosemount 8750WA Magmeter Sensor delivers reliability for water and wastewater industriesOperationTh
20Rosemount 8750WAJanuary 2014www.rosemount.com Table 4. Rosemount Wafer Sensor dimensions - inchesSize, descriptionOverall length DIM “A” Body Ø DIM
21Rosemount 8750WAJanuary 2014www.rosemount.comMagnetic Flowmeter sizingFlowmeter sizingBecause of its effect on flow velocity, sensor size is an impo
22Rosemount 8750WAJanuary 2014www.rosemount.com Table 8. Line size vs. velocity/rateNominal line size in inches (mm)Minimum/maximum flow rateGallons p
23Rosemount 8750WAJanuary 2014www.rosemount.comNorth American certificationsNoteFor the 32E transmitters with a Local Operator Interface (LOI), the lo
24Rosemount 8750WAJanuary 2014www.rosemount.comUpstream/downstream piping lengthTo ensure specification accuracy over widely varying process condition
25Rosemount 8750WAJanuary 2014www.rosemount.comMaterial selectionSee Table 11 for information on Liner types, Table 12 for information on Electrode Ma
26Rosemount 8750WAJanuary 2014www.rosemount.comOrdering informationModel Product description8750WA Magnetic Flowmeter System for Water IndustriesCode
27Rosemount 8750WAJanuary 2014www.rosemount.comCode Line size0051/2 -in. (15 mm) - Only available in PTFE010 1 -in. (25 mm)015 11/2 -in. (40 mm)020 2
28Rosemount 8750WAJanuary 2014www.rosemount.comCode OptionsDisplaysM4 Local Operator InterfaceM5 LCD Display onlyRemote Mounting OptionsB6 Stainless S
29Rosemount 8750WAJanuary 2014www.rosemount.com(6) Available in line sizes up to 24-in.(7) Available in line sizes up to 24-in.(8) FM marked, CSA mark
3Rosemount 8750WAJanuary 2014www.rosemount.comFlanged sensorsFlanged sensors are fabricated from stainless and carbon steel and welded to provide a he
30Rosemount 8750WAJanuary 2014www.rosemount.comTaggingTransmitter tag character height is 0.125 -in. (3.18 mm). See Configuration Data Sheet for chara
31Rosemount 8750WAJanuary 2014www.rosemount.com
Standard Terms and Conditions of Sale can be found at www.rosemount.com\terms_of_saleThe Emerson logo is a trade mark and service mark of Emerson Elec
4Rosemount 8750WAJanuary 2014www.rosemount.comRosemount Magmeter Diagnostics reduce costs & improve outputRosemount Magmeters provide device diagn
5Rosemount 8750WAJanuary 2014www.rosemount.comOptional Rosemount Mag DiagnosticsSMART meter verificationVerifying magmeter calibration has traditional
6Rosemount 8750WAJanuary 2014www.rosemount.comSMART meter verification improves magnetic flowmeter verification practiceDiagnostic in LOIDiagnostic in
7Rosemount 8750WAJanuary 2014www.rosemount.comGrounding/wiring diagnostic improves installation practicesDiagnostic in LOIDiagnostic in AMS Device Man
8Rosemount 8750WAJanuary 2014www.rosemount.comHigh process noise diagnostic improves process managementDiagnostic in LOIDiagnostic in AMS Device Manag
9Rosemount 8750WAJanuary 2014www.rosemount.comRosemount 8750WA specificationsFunctional specificationsServiceWater and water-based fluidsLine sizes1/2